Tested with UCCX 12-5 for ST 13.4.15
HW specs of the tested VM
...
Following are the load test result
Note: different elapsed time noted for different calling number in APi as can viewed in below ss of result view table as well.
Ramp-up Period (secs) | Number of Threads (Users) | Elapsed time of current running test | Loop Count | |
---|---|---|---|---|
1 | 20 | 2 sec | Callers are visible | 1 |
1 | 50 | 6 sec | Callers are not visible in caller list during load test different elapsed time noted for different number in APi as can viewed in below ss | 1 |
1 | 300 | 29 sec | Callers are not visible in caller list during load test | 1 |
1 | 500 | 50 sec | Callers are not visible in caller list during load test | 1 |
5 | 500 | 47 sec | Callers are not visible in caller list during load test | 1 |
60 | 500 | 1 min 12 sec | Callers are visible in caller list during load test with delay of 5 to 6 secs | 1 |
100 | 500 | 1 min 39 sec | callers are visible during load test | 1 |
1 | 1000 | 1 min 35 sec | Callers are not visible in caller list during load test | 1 |
1 | 2000 | 02 min 39 sec | Callers are not visible in caller list during load test | 1 |
1 | 100k | 1hour 52 mins | Callers and caller list are not visible after the load test. Container of caller list goes into unhealthy state. | 1 |
...
Ramp-up Period (secs) | Number of Threads (Users) | Elapsed time of current running test | Loop Count | |
---|---|---|---|---|
20 mins (1200) | 100k | 1 hr 19 mins | Callers and caller list are not visible after the load test. Container of caller list goes into unhealthy state. after the load container is in healthy state and callers are visible in caller list later it went into again in unhealthy state, container status behavior is inconsistent | 1 |
26 mins(1600sec) | 100K | 5 hour 55mins | Callers and caller list are not visible after the load test. Visible after 20 mins | 1 |
24 hours (86400) | 100k | 1 | ||
100k | 1 | |||
Later tested Again with different calling number Results are given
...
This is result for 100k threads and Ramp-up 20 mins, user faced issues for many threads in this load test “connection reset” error
...
Load test for 24 hours 1252397