Solutions Pre-requisite
...
For a simplex (single server) deployment, minimum and recommended hardware requirements are as follows:
Minimum | Recommended | |
---|---|---|
vCPU | 4 Cores | 8 Cores |
vRAM | 8 GB | 16 GB |
vDisk | 40 GB | 160 GB |
For a redundant deployment, two servers of the same specifications (as mentioned above) are needed.
...
Following are the prerequisites for setting up a Generic Connector under different deployment profiles.
Hardware Sizing | |
---|---|
For up to 250 concurrent agents | 8 vCPU, 16 GB RAM, 150 GB HDD |
Software Requirements | |
| |
Certificates for HTTPS | |
| |
System Access Requirements | |
|
System Access Requirements
Following ports should remain open on the Firewall. The local security policy and any antivirus should also allow open communication on the following ports:
Type | Source Host | Source Port | Destination Host | Destination Port |
---|---|---|---|---|
TCP | <Client Application> | any | EF Connector | 61616/61614 |
TCP | EF Connector (B) | any | EF Connector | 61616/61614 |
HTTP | For status monitoring from any machine | EF Connector | 8162 | |
XMPP | EF Connector | any | Cisco Finesse | 5222, 5223, 7071, 7443 |
HTTP/S | EF Connector | any | Cisco Finesse | 80, 8080, 443, 8443 |
NTP | EF Connector | any | NTP Server | 123 |
DNS | EF Connector | any | DNS Server | 53 |
Spring Port | EF Connector | any | EF Connector | 8112 |
- <Client Application> is a machine running client application of EF Connector. For server-based applications like Siebel, it’s Siebel Communication Server. For desktop-based applications, it’s the machine address of the agent desktop running the desktop application.
- In a redundant deployment, both EF Connector instances communicate with each other on the same TCP OpenWire port 61616. In the table above, it’s mentioned as EF Connector (B) ⇒ EF Connector.
- These are defaults set in EF Connector, but you can always change the default configuration.
...
Generic Connector Configuration should look like this, For a detailed description of the GC please consult properties
Property | Value |
ACTIVEMQ_TIMEOUT | 10000 |
GRC_CONSUMER_PRIORITY | 127 |
RANDOMIZE | false |
PRIORITY_BACKUP | true |
ACTIVEMQ1 | primary-url-of-amq:port |
ACTIVEMQ2 | secondary-url-of-amq:port |
Configurations for Site-2
Primary-AMQ: broker-1, Secondary-AMQ: broker-2, For a detailed description of the GC please consult Connector Configuration Parameters (Environment Variables)
Property | Value |
ACTIVEMQ_TIMEOUT | 10000 |
GRC_CONSUMER_PRIORITY | 100 |
RANDOMIZE | false |
PRIORITY_BACKUP | true |
ACTIVEMQ1 | primary-url-of-amq:port |
ACTIVEMQ2 | secondary-url-of-amq:port |
Failover Scenarios
The following table shows different failover scenarios and their impact on the Connector Clients.
No. | Scenario | Behavior |
1 | AMQ-1 is down while GC-1 is active | AMQ-2 will take over. GC-1 will automatically connect to AMQ-2 and all client requests will be processed by the same GC-1 instance because of its higher consumer priority. Request Flow: Client-App → AMQ-2 → GC-1 Response Flow: GC-1 → AMQ-2 → Client-App |
2 | AMQ-2 and GC-1 are down while AMQ-1 and GC-2 are up | AMQ-1 will take over and all client requests will be processed by GC-2 because it has the second-highest priority after GC-1. Request Flow: Client-App → AMQ-1 → GC-2 Response Flow: GC-2 → AMQ-1 → Client-App |
3 | Both AMQ-1 and GC-1 are down | AMQ-2 and GC-2 will start receiving requests. GC-2 will acquire all agent’s XMPP subscriptions and will start processing requests. Request Flow: Client-App → AMQ-2 → GC-2 Response Flow: GC-2 → AMQ-2 → Client-App |
4 | GC-1 restores | GC-1 will start receiving requests and will grab the XMPP connection of all the active agents because of its higher consumer priority. GC-2 will again be in stand-by mode. |
5 | The link between Connector-1 and Connector-2 is down | In this case, the AMQ network of brokers will not be functional and GCs won’t be able to communicate to sync agents either. So, both GCs will be functioning independently |
6 | AMQ-1 restores while GC-1 is still down | If AMQ-2 is active and the client application is connected to AMQ-2 then all requests will be processed by GC-2 even though GC-1 is active and connected to AMQ-1. Request Flow: Client-App → AMQ-2 → GC-2 Response Flow: GC-2 → AMQ-2 → Client-App |
7 | GC-1 is down while both AMQs are active | Requests will be processed by GC-2 going through the network of brokers. Request Flow: Client-App → AMQ-1 → AMQ-2 → GC-2 Response Flow: GC-2 → AMQ-2 → AMQ-1 → Client-App |
8 | GC-2 is down while both AMQ are active | In active-passive mode, it will have no effect on request and response flow. Because AMQ-2 doesn’t get any request from Client-App until AMQ-1 goes down. |
Failover is handled in a way if any component goes down, passive components take over in a seamless way.
...
For GC-1, the configuration would look like this, For a detailed description of the GC please consult Connector Configuration Parameters (Environment Variables)
Property | Value |
ACTIVEMQ1 | [AMQ-1]:61616 |
ACTIVEMQ2 | [AMQ-2]:61616 |
GRC_CONSUMER_PRIORITY | 127 |
PRIORITY_BACKUP | true |
Finesse_1 | http://Finesse-1/finesse/api/ |
SERVER_ADDRESS_1 | Finesse-1 |
Finesse_2 | http://Finesse-2/finesse/api/ |
SERVER_ADDRESS_2 | Finesse-2 |
For GC-2, the configuration would look like this, For a detailed description of the GC please consult Connector Configuration Parameters (Environment Variables)
Property | Value |
ACTIVEMQ1 | [AMQ-2]:61616 |
ACTIVEMQ2 | [AMQ-1]:61616 |
GRC_CONSUMER_PRIORITY | 100 |
PRIORITY_BACKUP | true |
Finesse_1 | http://Finesse-2/finesse/api/ |
SERVER_ADDRESS_1 | Finesse-2 |
Finesse_2 | http://Finesse-1/finesse/api/ |
SERVER_ADDRESS_2 | Finesse-1 |
Where [AMQ-1] should be replaced with the IP / machine-name of ActiveMQ-1 and [AMQ-2] should be replaced with the IP / machine-name of ActiveMQ-2. Finesse-1 is the IP/name of the Finesse-1 server and Finesse-2 is the IP/name of the Finesse-2 server.
...
We have achieved it using ActiveMQ configurable properties specifically Consumer priority, Priority Backup, and building a Connector Sync mechanism in Generic Connector.
Failover Scenarios
No. | Scenario | Behavior |
1 | AMQ-1 is down while GC-1 is active | AMQ-2 will take over and all client requests will be processed by the same GC-1 instance because of its higher consumer priority. |
2 | Both AMQ-1 and GC-1 are down | AMQ-2 and GC-2 will start receiving requests. GC-2 will acquire all agent’s XMPP subscriptions and will start processing requests. |
3 | GC-1 restores | Connector-2 will continue to process requests until connectivity between the Client application and Connector-2 is lost or Connector-2 is down. |
4 | The link between Connector-1 and Connector-2 is down | Both connector instances serve requests independently. |
5 | AMQ-1 restores while GC-1 is still down and AMQ-2 is also down | The client will send a request to AMQ-1. AMQ-1 will send the request to GC-2 because GC-1 is down. Request Flow: Client-App-1 → AMQ-1 → GC-2 Response Flow: CGC-2 → AMQ-1 → Client-App-1 |
6 | GC-1 is down while both AMQs are active | The request flow will be the same as no. 5 |
7 | GC-2 is down while both AMQs are active | AMQ-2 requests will be redirected to AMQ-1 and GC-1 will handle all requests. Request Flow: Client-App-2 → AMQ-2 → AMQ-1 → GC-1 Response Flow: GC-1 → AMQ-1 → AMQ-2 → Client-App-2 |
Deployment Steps
- Download the docker-compose an env file from Google-Drive
- Download the required deployment folder
...
- Create a folder on a Linux machine in any path of your inside root.
- Place the files inside the created folder as follows:
- Open env.txt file with text editor
- Make the desired changes and update the file
- run the command chmod 755 ./deploy.sh
now run the ./deploy.sh file and you can see after completion your docker image is running
- For Active MQ deployment
- For Rest deployment
- After that run the following commands to edit the ActiveMQ configuration
...
Connector Configuration Parameters (Environment Variables)
Parameter | Default Value | Description |
NUMBER_OF_LICENSES | 1000 | |
CUSTOMER_NAME | Haseeb | |
KEY | ASDFGHJKLZXCVBNM234RFGHUIOKJMNBFEWSDFGHNJMNBV | License key. Must be obtained from EF Team |
Finesse_1 | https://Finesse-X-DN/finesse/api/ | Primary Finesse URL for Site A |
Finesse_2 | https://Finesse-X-DN/finesse/api/ | Primary Finesse URL for Site B |
ACCESS_TOKEN_URL | https://192.168.1.104:1126/getaccesstoken | |
FINESSE_REQUEST_TIMEOUT | 3000 | Finesse requested a timeout (in mili-seconds) |
FINESSE_HEARTBEAT_SLEEP | 5 | Delay in ping to finesse servers (seconds) |
ByPass_SSL | ture | Bypass SSL Certificate if finesse url is https and self signed certificate is used, in case of false Import SSL certificate to JVM if needed |
ACTIVEMQ1 | localhost:61616 | ActiveMQ Primary URL |
ACTIVEMQ1 | localhost:61616 | ActiveMQ Secondary URL |
ACTIVEMQ_TIMEOUT | 30000 | ActiveMQ connection timeout (in milliseconds) |
GRC_CONSUMER_PRIORITY | 127 | Connector1 Queue consumer priority (Used for primary, secondary deployment of GC)(0-127) |
PRIORITY_BACKUP | true | To connect with its primary GC |
RANDOMIZE | false | for failover url |
PREFETCH_SIZE | 20000 | Prefect Size of the messages |
AGENT_STATES_PUBLISHER_DURATION | 5000 | Time after which, states of all agents would be published on topic (In Milliseconds) |
GC_HEARTBEAT_TIMEOUT | 10000 | GC heartbeat timeout |
AGENT_INACTIVITY_DURATION | 30 | Agent inactivity time (in seconds) |
GC_HEARTBEAT_SLEEP | 10000 | gc heartbeat thread sleep time |
AGENT_INACTIVITY_TIME_SWITCH | false | Agent inactivity switch |
DEFAULT_NOT_READY_REASON | 19 | default reason code for not ready (Must be defined in finesse) |
DEFAULT_LOGOUT_REASON | 70 | Default reason code for force logout |
AGENT_XMPP_SUBS_TIME | 10000 | Agent XMPP Subscription Time |
USE_ENCRYPTED_PASSWORDS | false | Use encrypted password |
CHANGE_STATE_ON_WRAPUP | true | Automatically change the state when wrap-up occurs |
LOGLEVEL | TRACE | Log Level |
GC_HEARTBEAT_TIMEOUT | 10000 | GC heartbeat timeout |
USE_ENCRYPTED_PASSWORDS | true | Use password encryption (3Des). (Must be same as in client.) |
CHANGE_STATE_ON_WRAPUP | true | Caller’s state change automatically on wrap-up |
MESSAGE_FORMAT | JSON | Message Format for communication. Expected formats DEFAULT, JSON, XML |
AGENT_LOGS_PATH | /app/logs/agents/ | Agent Logs Storage path |
AGENT_LOGS_LEVEL | TRACE | Agent Logs Level |
AGENT_LOGS_MAX_FILES | 10 | Max No of Files per agent for logs |
AGENT_LOGS_FILE_SIZE | 10MB | Max file size for agent logs |
XMPP_PING_INTERVAL | 3 | Interval in seconds between XMPP server pings |
ADMIN_ID | Administrator | The username of the administrator account the would be used for phonebook and contact APIs |
ADMIN_PASSWORD | Expertflow464 | The password of the administrator account would be used for phonebook and contact APIs |
Supervisor_initiated_NotReadyReasonCode | 19 | Reason code for supervisor state change to Not_Ready |
Supervisor_initiated_LogOutReasonCode | 20 | Reason code for supervisor state change to Log_Out |
UCCX_SERVER_IP | 192.168.1.29 | For queue stats in case of UCCX |
UCCX_SERVER_USERNAME | Administrator | |
UCCX_SERVER_PASSWORD | Expertflow464 | |
UCCX_DB_USERNAME | uccxhruser | |
UCCX_DB_PASSWORD | 12345 | |
UCCX_DB_RETRY_ATTEMPTS | 2 | |
UCCX_DB_TIMEOUT_CONNECTION | 1800 | |
COMMUNICATION_FORMAT | REST | JMS | |
SPRING_PORT | 8112 | |
REDIS_URL | redis-master.ef-cti.svc | |
REDIS_PORT | 6379 | |
REDIS_PASSWORD | Expertflow123 | |
SQL_SERVER | 192.168.1.89 | For Skill groups and supervisor list |
DATABASE | uc12_awdb | |
DATABASE_TABLE | Skill_Group | |
DATABASE_USER_NAME | sa | |
DATABASE_USER_PASSWORD | Expertflow464 | |
KEY_STORE_TYPE | PKCS12 | |
KEY_STORE | D:\\EF_Project\\GC4.4\\Generic Connector\\certs\\store\\clientkeystore.p12 | |
TRUST_STORE | D:\\EF_Project\\GC4.4\\Generic Connector\\certs\\store\\client.truststore | |
KEY_STORE_PASSWORD | changeit | |
TRUST_STORE_PASSWORD | changeit | |
PRIVATE_KEY_STRING | key_value | |
ISSUER | ef-chat | |
EXPIRY | 300 | |
PEP_BASE_PATH | http://192.168.50.31:8113 | |
AOP_CALLBACK | /ef-voice/fnb-cme/submit-gc-event/v1 | |
AXL_URL | https://192.168.1.26:8443/axl/ | |
AXL_USER | administrator | |
AXL_PASSWORD | Expertflow464 | |
LD_LIBRARY_PATH | /app |
MX Monitoring